Effect the Size of Lead Particles on Gamma –Ray Absorption Coefficient
DOI:
https://doi.org/10.5281/zenodo.10651431Keywords:
polymer, Lead, gamma-rays, liner attenuation coefficientAbstract
The present work deals with the shielding properties of polymer composites using gamma rays emitted from (137Cs), narrow beam. Polymer composites with Lead in deferent size (powder and shot ball), in different lead weights ratio (0, 50, and 70) % wt as filler had been prepared. to clarify the difference in the spectrum absorption gamma rays through the process of exponential equations graphic performance of the count rate as a function of composite thickness. The incident and transmitted intensities were measured using gamma spectrometer incorporate Sodium Iodide with traces of Thallium Na I(Tl) scintillator detector. Linear attenuation coefficients (μ) for gamma ray were calculate. The experimental results show that gamma-ray attenuation coefficient is inversely proportional with the size of Pb particle size due to the reduction of the spaces between the lead particles. Results also indicated that the constructed materials show good radiation protection properties
References
W.Schimpf, D.J.Mackenzie, M.Z.Karson, B.R.Schmidt, J.E.Casteras &J.J.Cullen ; "A guide to the use of lead for radiation shielding", NewYork, (2001).
Canadian Nuclear Safety Commission "Introduction to Radiation" Minister of Public Works and Government Services Canada (PWGSC) catalogue number CC172-93/2012 ISBN 978-1-100-21572-3.
Noor A.zman, N.Z. S.A. Siddiqui.R. Hart.R, Low,I.M,. Microstructural Design of Lead Oxide–Epoxy Composites for RadiationShielding Purposes. Wiley Periodicals2013: Inc. J. Appl. Polymer.
K.H.Mahdi, Z.S.Ahmed , A.F.Mkhaiber "Calculation and Study of Gamma ray Attenuation Coefficients for Different Composites " article Ibn Al-Haitham Journal for Pure and Applied Science, No. 3 Vol. 25 (2012).
Erol A, Pocan I, Yanbay E, Ersoz, O.A, Lambrecht, F.Y. Radiation shielding of polymer composite materials with wolfram carbide and boron carbide. Radiat Prot Environ 2016;39:3-6.
] Donk Yu, Chang Shu-Quan,) , Zhang Hong-Xu, RenChao Kang Bin , DAI Ming-Zhu , DaiYao-Dong , .Effects of WO3 particle size in WO3/epoxy resin radiation shielding material., Chin. Phys. Let(2012);Vol. 29, No.
Harish V, Nagaiah N, Prabhu T B , T.K.Varughese ,.Preparation and characterization of lead monoxide filled unsaturated polyester based polymer composites for gamma radiation shielding application .J application polymer Sci 2009 ; 112,no.3:1503-1508.
Hussain HS, Jaffer HI,. 2011. Dependence of gamma-ray absorption coefficient on the size of lead particle. Baghdad Science Journal. 8, 613
Mutlak D. and Ali A., Study the enhancement of the radiation shielding afforded to epoxy /lead composites. J. of university of Anbar for pure science 2013; 7:NO.2.
AL fakhar M, IbrahimH, Mohan A ,2016 . Linear attenuation coefficient calculation for both pure silicon (Si) and silicone supported with lead.,journal (IJAIEM) ,vol 5,Iss.4, pp.146-150
Downloads
Published
How to Cite
Issue
Section
License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
You are free to:
- Share — copy and redistribute the material in any medium or format
- Adapt — remix, transform, and build upon the material
- The licensor cannot revoke these freedoms as long as you follow the license terms.
Under the following terms:
- Attribution — You must give appropriate credit , provide a link to the license, and indicate if changes were made . You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
- NonCommercial — You may not use the material for commercial purposes .
- No additional restrictions — You may not apply legal terms or technological measures that legally restrict others from doing anything the license permits